Index:Water pressure: 0.02~0.8MPa Power supply: 1 piece of 3.6V/6A/h (3.6V/2A/h) lithium dry battery can be used for more than 400 thousand times (5 year or so), there is no need to change battery during this 5 years. Induction distance: 200~600mm Temperature of preventing being scalded: 0~55°C(element by choice) Diameter of in-out let pipe: G1/2ˊ
Method of use:After the inducting shower is installed correctly, when the user goes under the shower, the shower can induct automatically and turn the water on; when leaving the shower, the shower will turn the water off automatically. When being used more than 1 minute , it will turn off automatically , if using again , it needs to be inducted again after keeping away the faucet . The water temperature and volume can be adjusted by the water-mixing handle under the shower. Maintenance :1. Keep the inducting shower clean, when blot is found, wipe the shower with soft clean cloth. 2. When the flux of the shower is too small, unload inducting box of the shower and flush it rightabout, take out the filtering core of the shower, wash it clean and install over again. 3. When the inducting distance is too near or distant, it can be adjusted through the resistor in the shower control box.
|